Instructions for Setting Up Communication with Refusol Inverters
Before you begin configuration, make sure you have thoroughly read and reviewed the following knowledge base pages:
Communication via RS485
Please ensure the following parameters are correctly configured:
- Protocol: Siemens/AEI
- Baud rate: 57,600
- Parity: 8E1 (8 data bits, Even parity, 1 stop bit)
Communication via Ethernet/Network
For network communication, note the following:
- Standard port 502 is not used, unless it can be changed in the inverter settings.
- If the port cannot be changed, use port 21062 instead.
Need More Help?
If you encountered any difficulties or need further assistance, here are some steps you can take:
Contact Support:
- Email: Reach out to our support team by emailing us at support@amperecloud.com. Provide as much detail as possible about the issue you're facing.
- Fill out a form: Complete our online support form. Please include all relevant information about your request, and our team will get back to you as soon as possible.
Share Your Feedback
If this article didn’t meet your needs or if you have suggestions on how we can improve, please let us know by submitting feedback. Your input helps us enhance our resources and support.